Distributor LocatorEnergy ReportContact UsProduct InfoLibrary FAQsOrder Status
Pittsburgh Corning FOAMGLAS
About FOAMGLAS Insulation - Advantages of FOAMGLAS Insulation
About FOAMGLAS® Insulation
Print this Page
HomeAbout FOAMGLAS Insulation
Advantages of FOAMGLAS® Insulation
FOAMGLAS® Insulation Solutions Center
Product Information Library
Product Technical Data
Material Safety Data Sheets
Product Data Sheets
Mechanical Specs
UL Through Penetration
Fire-Stop
Approved Systems


Technical Newsletters
Technical ServicesSuccess StoriesAbout Pittsburgh CorningSite Map
Free Energy Analysis Report

Free Energy Survey

Product Technical Data

Mechanical Specs


Physical and Thermal Properties of FOAMGLAS® Insulation
Physical Properties USA Metric SI ASTM Test
Absorption of moisture (% by volume) 0.2%
Only moisture retained is that adhering to surface cells after immersion.
C240
Water-vapor permeability 0.00
perm-in
0.00
perm-in
  E96 †
Acid resistance Impervious to common acids and their fumes, except hydrofluoric acid.
Capillary None None None  
Combustibility Non-combustible, will not burn.   E136
Composition Pure glass, totally inorganic, contains no binder.  
Compressive strength average for standard material 90 psi 6.3 kg/cm2 620 kPa C165, C240, C552-00
Strength for flat surfaces capped with hot asphalt; different capping will give different values. For curved surfaces and pipe supports, contact PCC.
Density, average 7.5 lb/ft3 120 kg/m3 120 kg/m3 C303
Dimensional stability Excellent — does not shrink, swell or warp.  
Flexural strength, block average 70 psi 4.9 kg/cm2 480 kPa C203,
C240
Hygroscopicity No increase in weight at 90% relative humidity.  
Linear coefficient of thermal expansion
(25 to 300°C)
5.0 x 10-6/°F 9.0 x 10-6/°K 9.0 x 10-6/°K E228
Maximum service temperature +900°F +482°C 755°K  
Modulus of elasticity, approximately 1.3 x 105 psi 9,300 kg/cm2 900 MPa C623
Shear strength No reliable recognized test method for determination of the shear strength for cellular glass exists at this time. Where shear strength is a design criterion, PCC should be contacted for recommendations.
Thermal conductivity Btu-in/hr·ft2·°F
0.29 @ 75°F
0.28 @ 50°F
kcal/m·h·°C
0.033 @ 0°C
0.034 @ 10°C
W/mK
0.039 @ 0°C
0.040 @ 10°C
C177, C518
Specific heat 0.20 Btu/lb·°F 0.20 kcal/kg·°C 0.84 kJl/kg·°K  
Thermal diffusivity 0.016 ft2/hr 0.0042 cm2/sec 4.2x10-7 m2/sec  
NOTE: Properties given at 75° F unless otherwise specified. Properties may vary with temperature. These values are average or typical values recommended for design purposes, and are not intended as specification or limit values. †E 96 Wet Cup Method/Procedure B


Certifications* and Approvals
FOAMGLAS® Insulation can be certified to conform to the requirements of:
  • ASTM C 552 “Specification for Cellular Glass Thermal Insulation”
  • Canadian Standard CAN/CGSB51.38M
  • Military Specification MIL-I-24244C, “Insulation Materials, Thermal, with Special Corrosion and Chloride Requirement”
  • Nuclear Regulatory Guide 1.36, ASTM C 795, C 692, C 871
  • Flame Spread 5, Smoke Developed 0 (UL 723, ASTM E 84), R2844; also classified by UL of Canada, CR1957
  • ISO 9001:2000
  • Through-Penetration Firestop Systems UL 1479 System Nos. CAJ5060, CAJ5069, CAJ5071 and System Nos. WL5038, WL5045, WL5046, WL5051, WL5067, WJ5011, WJ5015
  • Board of Steamship Inspection (Canada) Certificate of Approval No. 100/F1-98
  • General Services Administration, PBS (PCD): 15250, Public Building Service Guide Specification, “Thermal Insulation (Mechanical)”
  • New York City Dept. of Bldgs., MEA #138-81-M FOAMGLAS® Insulation for piping, equipment, walls and ceilings
  • New York State Uniform Fire Prevention and Building Code Dept. of State (DOS) 07200-890201-2013
  • City of Los Angeles General Approval RR22534
FOAMGLAS® Insulation is identified by Federal Supply Code for Manufacturers (FSCM 08869).
*Written request for certificate of compliance must accompany order.


Mechanical Specification Index
Call Pittsburgh Corning Corporation for copies of specifications at 800-359-8433.
GENERAL
Specification #
Title
Section
1. I-H/C-89-02-01 Specification Guidelines for FOAMGLAS® Insulation (genspec.doc)

GENERAL

PIPING
Specification #
Title
Section
1. I-C-78-02-01 Specification for Application of FOAMGLAS® Insulation on Liquid Oxygen or Nitrogen Piping (pilnox.doc)

PIPING

2. I-C-82-07-01 Application of FOAMGLAS® Insulation to Chilled Water Pipes (picwp.doc)

PIPING

3. I-H-82-11-01 Guidelines for Application of FOAMGLAS® Insulation to Heat Traced Piping (piht.doc)

PIPING

4. I-S-83-07-01 Guidelines for Using FOAMGLAS® Insulation at Pipe Hangers and Supports (pipe supports and hangers.doc)

PIPING

5. I-H/C-86-09-01 Specification for Insulation of Piping Systems for Freeze Protection and Process Control (pifrzpr.doc)

PIPING

6. I-DB-89-02-02 Specification for FOAMGLAS® Insulation in Underground Direct Burial Applications (pidbcgi.doc)

PIPING

7. I-U-GL-701 Specification for the Application of FOAMGLAS® Insulation in Shallow Trench, Vault, and Tunnel Applications (pitrench)

PIPING

8. I-P-ST-327 Specification for the Application of FOAMGLAS® Insulation to Aboveground Steam Piping (piagstm.doc)

PIPING

9. I-P-LNG Specification for the Application of FOAMGLAS® Insulation on Liquid Natural Gas Piping (pilng.doc)

PIPING

10. I-H-90-03-01 Specification for the Application of FOAMGLAS® Insulation to Stainless Steel Piping (pissp.doc)

PIPING

11. DUAL - HW/CW Application of FOAMGLAS® Insulation to Dual System Chilled and Hot Water Pipes (pidualhwcw.doc)

PIPING

12. I-U-GL-702 (PERF) Specification for the Application of FOAMGLAS® Insulation in Shallow Trench, Vault, and Tunnel Applications (pitrench perf.doc)

PIPING

SPECIAL
Specification #
Title

Section
1. I-H-82-08-01 Application of FOAMGLAS® Insulation to Systems Utilizing Heat Transfer Fluids or Hot Oil (sphttrn.doc)

SPECIAL

2. A-88-11-01-01 Specification for Factory Application of PITTWRAP® Jacketings to FOAMGLAS® Insulation Pipe Cover (spfpwj.doc)

SPECIAL

3. I-H/C-90-01-02 Specification Guidelines for the Application of FOAMGLAS® Insulation to Spherical Vessels Using the Fully Adhered Method (sphere.doc)

SPECIAL

4. I-C-90-08-01 Insulation of Air Conditioning Ducts Using FOAMGLAS® Insulation (spacdu.doc)

SPECIAL

5. I-P-EO-322 Guidelines for Application of FOAMGLAS® Insulation to Ethylene Oxide Piping and Equipment for Fire Protection (fpeo.doc)

SPECIAL

6. I-EO-93-04-02 Guidelines for the Application of FOAMGLAS® Insulation to Ethylene Oxide Piping and Equipment (stdeo.doc)

SPECIAL

7. I-FP-1998 Specification Guidelines for FOAMGLAS® Insulation Used in Fire Protection Applications for Piping, Tanks, and Vessels (firep.doc)

SPECIAL

StrataFab® System/ ADVANTAGE® System
Specification #
Title

Section
1. I-SF-89-02-03 Specification Guidelines for the StrataFab® System Using FOAMGLAS® Insulation (stfbgen.doc)

STF/AD

2. I-SF-90-07-02 Application of the StrataFab® System to Piping and Equipment Utilizing Heat Transfer Fluids (stfbpiht.doc)

STF/AD

3. ADVANTAGE® System Specification Guidelines for the FOAMGLAS® Insulation ADVANTAGE® System (advan.doc)

STF/AD

TANKS
Specification #
Title

Section
1. I-H-77-04-02 Above Ambient Tank Insulation Application Specification (tkaa.doc)

TANKS

2. I-C-79-07-01 Insulation of a Below Ambient Storage Vessel Using FOAMGLAS® Insulation (tkbav.doc)

TANKS

3. I-H-81-06-01 Guidelines for Securing FOAMGLAS® Insulation to Roofs of Tanks Operating Above 70° F (21° C) (tktrf.doc)

TANKS

4. I-H-84-12-02 Insulation of Hot Tanks Using Weld Pin Securement (tkwp.doc)

TANKS

5. I-H-85-01-02 Specification for the Application of FOAMGLAS® Insulation to Caustic Liquid Storage Tanks up to 350° F (177° C) (cutank.doc)

TANKS

6. I-C-85-05-01 Specification for Application of FOAMGLAS® Insulation to Base and Shell of Refrigerated Liquid Storage Tanks (tkrfbs.doc)

TANKS

7. I-H-85-09-01 Specification for Insulation of Hot Tank Bases Using FOAMGLAS® Insulation (tkmtb.doc)

TANKS

8. I-TK-CW1 Insulation of a Chilled Water Storage Tank Using FOAMGLAS® Insulation (tkcw1.doc)

TANKS

9. I-TK-CON Insulation of a Concrete Storage Tank Using FOAMGLAS® Insulation (tkcon.doc)

TANKS

CYCLIC
Specification #
Title
Section
1. I-CYC-92-03-01 Specification for the Application of FOAMGLAS® Insulation to Piping Cycling from -150° F to 700° F (cycpip.doc)

CYCLIC

2. I-CYC-94-01-02 Specification for the Application of FOAMGLAS® Insulation to Cyclic Vessels Operating from -95° F to 350° F (-71° C to 177° C) (cycvs.doc)

CYCLIC


Home | About FOAMGLAS® Insulation | Technical Services
Success Stories | About Pittsburgh Corning | Site Map

Distributor Locator | Energy Analysis Report | Contact Us | Product Info

© 2004 Pittsburgh Corning Corporation